| SKU | SRT1500XLI |
| Brand | APC |
| Model | [SRT1500XLI] UPS “APC” Smart-UPS SRT 1500VA/1500Watts |
| Output Power Capacity | 1500Watts/1500VA |
| Nominal Output Voltage | 230V |
| Topology | Double conversion online |
| Output Connections | 6 IEC 60320 C13 |
| Nominal Input Voltage | 230V |
| Input Connections | IEC 60320 C14 |
| Input Voltage Range for Main Operation | 100…275 V |
| Typical Recharge Time | 3hour(s) |
| Control Panel | Multifunction LCD status and control console |
| Height | 43.2 cm |
| Width | 8.5 cm |
| Depth | 50.5 cm |
| Weight | 20.5 kg |
| Warranty | 3 years repair or replace (excluding battery) and 2 years for battery |
APC Smart-UPS SRT 1500VA 230V (SRT1500XLI)
Safety and General Information
- Adhere to all national and local electrical codes.
- All wiring must be performed by a qualified electrician.
- Changes and modifications to this unit not expressly approved by APC could void the warranty.
- This SRT1500XLI is intended for indoor use only.
- Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
- Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
- For a UPS with a factory installed power cord, connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
- The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
- The batteries are heavy. Remove the batteries before installing the UPS and external battery packs (XLBPs), in a rack.
- Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs.
- Always install peripheral equipment above the UPS in rack-mount configurations.
- Additional safety information can be found in the Safety Guide supplied with this unit.
Deenergizing safety
- The SRT1500XLI contains internal batteries and may present a shock hazard even when disconnected from AC and DC power.
- The AC and DC output connectors may be energized by remote or automatic control at any time.
- Before installing or servicing the equipment check that the:
- Input circuit breaker is in the OFF position.
- Internal UPS the batteries are removed.
- XLBP battery modules are disconnected.
Electrical safety
- For models with a hardwired input, the connection to the branch circuit (mains) must be performed by a qualified electrician.
- Have a proper grounding for input socket for the models with pluggable power cords.
- The protective earth conductor for the UPS carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will typically be green and with or without a yellow stripe.
- The UPS input ground conductor must be properly bonded to protective earth at the service panel.
- If the SRT1500XLI input power is supplied by a separately derived system, the ground conductor must be properly bonded at the supply transformer or motor generator set.
- Leakage current for a pluggable Type A UPS may exceed 3.5 mA when a separate ground terminal is used.
Click here to learn more about APC Support